Alkalinity Doser: how it works and protects
16.1 How it works
With the doser on, in Normal or Fast mode, the device measures KH every hour, 24 hours a day, and doses right after each measurement. The interval and the time window you chose on the Target Alkalinity screen stay stored and apply again when you turn the doser off (sections 8.3 and 8.4).
With every measurement it learns a little more about your aquarium: how much it consumes at each hour of the day — more with the lights on, when corals calcify, and less at night. That lets the doser stay one step ahead: it doses what the aquarium will consume until the next measurement, instead of chasing what is already missing. The result is a stable KH, with no sudden rises or drops.
It also checks, measurement by measurement, how much each dose really raises KH, and makes up for small differences between the yield you entered and the real one. A value that is far off is not something it can fix: entering the right yield still matters (section 15.5).
What it does in each situation
The doser looks at where KH stands in relation to the target and to the tolerance margin you chose on the Target Alkalinity screen:
- KH dropped over the last few hours — during a consumption peak in the late afternoon, for example: it gives that drop back right away, without waiting.
- Reading above the target plus half the margin — with the target at 8.00 and the margin at 0.15, from 8.08: it does not dose that hour, and the next measurement decides again.
Hour without a measurement, hour without a dose
If a measurement does not happen — a failure, the device switched off —, that hour goes without a dose, and nothing is made up all at once later. The next measurement picks up from the current reading.
16.2 If you have another replenishment system
There is no need to tell the device anything: it notices on its own.
| Your system | What the doser does |
|---|---|
| Calcium reactor with CO2 Port control on (Chapter 17) | The port takes care of KH. The doser stays in reserve and only steps in after three measurements in a row with KH below the band — for example, because the CO2 ran out. When the port copes again, the doser stops on its own |
| External dosing pumps, a reactor without port control, or kalkwasser | The doser only tops up what is missing. If your system covers everything, it hardly doses at all. If it covers half, the doser makes up the other half |
At first, with another system already replacing everything, the doser may dose a little until it understands your aquarium; after that it stays practically idle. Since it can only add, KH may end up a little above target, within your tolerance margin — that is normal.
16.3 The first day and day to day
| Situation | What happens |
|---|---|
| First hours | Right after it is turned on, the doser already starts dosing, learning from the stored measurements and from the new ones. In about one day it knows your aquarium's rhythm |
| Restarting the device, calibrating the probe or changing the target | Nothing special: the next measurement decides like any other. The hours the device was off have no dose |
| Turning CO2 Port control on or off | It starts learning again and, in about a day, knows the aquarium's rhythm once more |
| Re-test | When a measurement is discarded and redone (section 8.2), the discarded reading does not dose. The measurement that confirms it decides the dose, already counting the time that has passed |
| Late measurement | If the measurement is delayed — for example, because another equipment cycle is in progress —, the dose goes out together with it |
16.4 Automatic protections
| Situation | What the doser does |
|---|---|
| Daily dosing limit | Everything the pump delivers in 24 hours has the ceiling you chose (section 15.2). When it reaches it, the doser pauses and warns you |
| Limit per dose | Each dose also has a ceiling, so that a wrong volume or a pump delivering too much does not turn into a large dose |
| KH above target | With the reading above the target plus half the margin, that hour goes without a dose; the next measurement decides again |
| No measurement | Does not dose: the dose only exists together with the measurement. If the measurement fails, you receive the error warning |
| Not enough product in the bottle | The dose is not given, and you are told (section 16.5) |
| Pump not calibrated | Does not run, and the home screen shows Calibrate |
| Very small dose | Doses smaller than 0.1 mL are not given: the pump cannot deliver them |
| Probe calibration overdue | Nothing changes in the doser. The calibration reminder arrives by e-mail |
16.5 What you see
On the home screen
The KH Buffer indicator shows how much is left in the bottle:
| The indicator shows | Meaning |
|---|---|
| Percentage | How much is left in the bottle. It turns red below the percentage in Custom. → Low KH Buffer %, and you get a warning |
| OFF | The doser is off, or the bottle has run out |
| Calibrate | The pump has not been calibrated yet and will not dose (section 15.4) |
In the event log, the e-mail and the graph
| Where | What appears |
|---|---|
| Event log | Each dose, with the volume and how much it raised — for example, Alkalinity doser: 10.2 ml (+0.102 dKH). When the daily dosing limit is reached, Alkalinity doser: daily maximum reached appears; when it frees up, Alkalinity doser: daily maximum released |
| Notification on Dosing | If you turn it on, you receive the e-mail of each measurement that had a dose, with the dose written in it — up to 24 a day. Great in the first days, to build confidence; then turn it off |