PART IIInstallation and pairing
CHAPTER 6

Choosing the data source

With the Display on your network, all that is left is telling it where the data comes from: which Aquarino KH or Controller it should mirror. You do that on the portal's Data source tab — or, on the touch models, right on the screen.

6.1 The three ways to point

MethodHow it works
List of devices on the networkThe Display searches for Aquarinos on your network and lists what it finds — just pick one. This is the normal path when everything is on the same network
Device IPYou type in the IP address of the KH or the Controller. Useful when automatic discovery does not find the device
Device UUIDYou paste the unique identifier (from the label or from the device's System screen). Works from any network, because the link then goes through the cloud

6.2 Local network or cloud?

The Display picks the best path on its own, always in this order: local network first — faster and independent of the internet — and cloud when it cannot reach the device directly. The LAN / CLOUD pill in the screen's bar shows which path is in use, and the portal shows the same state.

BadgeMeaning
LANReading the device directly, over your network — works even without internet
CLOUDReading through the Aquarino cloud — the path taken when the Display is on another network
No sourceNo device configured yet

6.3 How many sensors, how often

  • The Display follows up to 24 sensors from the source.
  • The device is read every 1 minute from the factory — adjustable to 5, 15, 30 or 60 minutes in the portal.
  • A sensor that goes 20 minutes without new data is considered stale: the value fades and the footer stamp warns you; if it stays silent, it leaves the rotation until it speaks again.